addVANTAGE Pro 6.4 Administrator Guide CHAPTER 4
The Tools Menu
The Data Acquisition Service
The Data Acquisition service is responsible for the replication of the raw data
from the RTUs and/or other addUPI servers into your system.
Figure 57 illustrates a general addVANTAGE Pro 6.4 installation from the data
acquisition perspective.
The wireless network shown in Figure 57 has a Telemetry Gateway that acts as
the network master. The gateway has an internal storage unit that keeps the
incoming data from the RTUs for a certain amount of time. Server A (also called
primary because it connects directly to the data source) periodically connects to
the gateway via TCP/IP and retrieves the data. This function on the server is
controlled by the Data Acquisition Service.
In this scenario, the Telemetry Gateway is a data provider (in fact, it is a server
from this point of view) and server A is a data consumer (a client from this point
of view). It is important to understand that the terms client and server have
different meanings depending on the context. From the Data Acquisition Service
perspective, the meanings are different from what we defined in this book as
client and server. To avoid further confusion, we didn’t show an addVANTAGE
client (the browser) in Figure 57. In fact, in this context, the addVANTAGE client
is irrelevant.
Figure 57. Raw Data Flow in an addVANTAGE Pro Installation
A data consumer can also be a data provider, as shown by the connection
between server A and server B. When server A acts as the server and server B is
the client, the data from server A will be replicated to server B.
Note: Only tag data can be transferred between servers and gateways at this level
(not events).
Configuring the Data Acquisition Service
Before you begin, you must know the IP address or the name of a remote server
you want to connect to. As already stated in this manual, it can be either a
Telemetry Gateway, another addVANTAGE Pro server, or in general an addUPI
server. You will also need an account and a password on the data source.
Note: addUPI is an http-based protocol used to transfer raw data between Adcon
telemetry components. You can get the protocol specification from Adcon
Telemetry free of charge.
Complete the following steps to add a data source to the Data Acquisition
Service:
1. Select Tools
Data Acquisition to display the Data Acquisition dialog
(Figure 58) showing a list of data sources.