CHAPTER 2
System Setup
50
A window similar to the one shown in Figure 21 is displayed.
Browse until you find the configuration file that was previously
saved from a backup operation, then select the file. Click Open to
upload the file to the gateway.
Note: The Restore operation is in fact identical to the Import from
addVANTAGE 3.46 operation described in Step 8 on
page 32.
About the LED Indicators
The A840 Telemetry Gateway has five LED indicators on its panel.
The indicators have a different significance based on whether the
device is operating in the usual Linux mode or in hermit mode (for
upgrading software and in other unusual circumstances).
“Advanced Functions” on page 53 provides more details about
the operating modes.
Linux Mode
LAN and ACT
These two LEDs are active only if you have a network cable
attached to the gateway and the network section is enabled. In
addition, the mains (110/220 volt) must be present, that is, the
gateway must not run out of its internal battery. The LAN LED is lit
while the Ethernet line is operational, and the ACT LED shows
activity on the Ethernet line.
USR and RUN
The USR LED lights when communication takes place over the RS-
485 line, that is, to or from the A440 Wireless Modem unit. The
RUN LED is currently not used in Linux mode.
PWR
Table 2 summarizes the PWR LED significance:
Table 2. The PWR LED Indicator
Mains PWR LED Battery
Present ON unknown