CHAPTER 3
Advanced Functions
84
request 2006 2/11/95 20:0:0
Dev 2006: incoming RF 255, outgoing RF 251
Time Thu Nov 2 20:12:21 1995
Data FF 00 00 51 72 E1 12 0C AF 04 01 72 E1 10 0C
AF 04 01
OK
Furthermore, if the INIT parameter is also specified after the date
and time, the station’s real-time clock will be resynchronized with
that of the gateway’s internal date and time:
request 2006 2/11/95 20:0:0 INIT
Dev 2006: incoming RF 255, outgoing RF 251
Time Thu Nov 2 20:12:21 1995
Data FF 00 00 51 72 E1 12 0C AF 04 01 72 E1 10 0C
AF 04 01
OK
Note: This is a forced-time initialization of an RTU. In practice it is
not needed, because the gateway does it automatically
when it is itself initialized by means of the time command
(see “SET TIME” on page 69).
An A720 device responds as follows:
request 6383
Dev 6383: incoming RF 255, outgoing RF 255
Time Fri Jun 2 17:01:35 2000
Data 4E 00 00 58 A5 60 01 00 00 86 00
OK
An A733 device responds as follows:
request 9471
Dev 9471: incoming RF 255, outgoing RF 122
Time Fri Jun 2 17:04:42 2000
Data 7F 00 00 00 00 00 00 00 00 59 00 16 AF 6B 20
01 00 00 00 A8 55 AF 13 A0 00 00 00 00
OK
Note: The internal FIFO of the A730MD RTUs is limited to 11 slots,
which means about 2-3/4 hours of stored data. The A720
series 2 can store up to 240 slots (about 2.5 days), while the
A733 RTUs can store up to 1024 slots (a little over 10 days).
Older data will be overwritten.
RSETIO
DESCRIPTION Acts upon the I/O ports of a remote device. It can switch a port to
input or output mode and can also switch a port configured as
output to a logical one or zero state.
P
ARAMETERS The RTU’s ID, the value of the data direction register (DDR), and
the value of the port itself (DATA). All values are in hex. The DDR
Seitenansicht 83