Advanced Functions
68
password will be transmitted unencrypted since HTTP is used. You
should not use the same username/password combination for
other purposes.
R
ETURNS Ok or error.
R
EMARKS None.
E
XAMPLES SENDNTF SYSLOG
Turns off sending notifications
SENDNTF SMS 600 NODEID 4366412345678
Requests sending notifications to phone number ++43-664-
12345678, the time between two SMS sent is at least 600 seconds.
Output format is the node ID.
SENDNTF SMS
Requests sending notifications as SMS, using the last supplied
configuration values
SENDNTF SMTP 30 PATHNAME [email protected]
[email protected] 192.168.1.2
Requests sending notfications as e-mail to [email protected], using
[email protected] as the sender e-mail address, the SMTP
server at IP address 192.168.1.2 and the default IP port for SMTP
servers (port 25). The time between two e-mails sent is at least 30
seconds. Output format is "RTU-Name/Sensor-Name".
SENDNTF HTTP 60 http://nowhere.adcon.at/cgi-bin/
notification.cgi
Requests sending notifications as HTTP request to the host
nowhere.adcon.at, without HTTP authentication.
SENDNTF HTTP 60 http://
nobody:[email protected]/cgi-bin/
notification.cgi
Requests sending notifications as HTTP request to the host
nowhere.adcon.at, logging in as user nobody using the password
nopasswd.
SET Commands
The SET command has many subcommands, because as its name
implies, it sets various parameters of the emu3ap application. Most
of the SET commands have a get form, in which only the