CHAPTER 3
Operations at the Application Level
69
subcommand is typed and the emu3ap application returns the
requested information.
SET TIME
DESCRIPTION Sets the internal real-time clock of the emu3ap.
P
ARAMETERS The time in the following format: dd/mm/yyyy hh:mm:ss (24-hour
clock format).
R
ETURNS OK or an error message.
R
EMARKS The year may be sent either in two- or four-letter format (for
example, 1999 or 99), but the four-letter format is preferred. In
addition, the emu3ap also accepts the year 2000 and years
thereafter as hundreds, for example, 100 for 2000, 101 for 2001,
and so forth. The date/time parameters may be sent with or
without leading zeros. The get variant TIME (with no parameters)
returns the current date and time of the device.
E
XAMPLE set time 4/6/2001 20:1:0
OK
time
Local time is: Sun Jun 4 20:01:07 2001
OK
SET FREQ
DESCRIPTION Sets the operating frequency and step of the gateway (this
parameter is further transmitted to the A440 Wireless Modem).
P
ARAMETERS The frequency and step, both in Hz.
R
ETURNS OK or an error message.
R
EMARKS The get variant FREQ (with no parameters) returns the actual
operating frequency.
E
XAMPLE set freq 433925000 25000
OK
freq
Frequency: 433925000, step: 25000
OK
In the example above, the gateway plus wireless modem
combination operates on 433.925 MHz with channel spacing of 25
kHz.