CHAPTER 3
Operations at the Application Level
85
and DATA bits must be OR-ed according to the required state of
the ports.
R
ETURNS The actual state of the port (in hex).
R
EMARKS This command is deprecated; it is supported only by the A730MD
devices and early A720 devices (series 1). New devices use the
more advanced PORT command.
E
XAMPLE rsetio 2003 0 0
DDR 02, REG 5F
OK
PORT
DESCRIPTION Acts upon the I/O ports of a remote device.
P
ARAMETERS The RTU’s ID, the byte code, and parameters (for some forms of
the command). All parameters are in decimal form (pay particular
attention to the byte code because it must be translated to
decimal).
R
ETURNS Status result, depends on command.
R
EMARKS This command is currently supported only by the A720 (series 2)
and A723 (series 3) addITs and A733 addWAVE RTUs.
E
XAMPLE port 9473 0
Dev 9473: incoming RF 255, outgoing RF 255
Value: 255, Error level: 0
OK
ANALOG
DESCRIPTION Acts upon the analog input ports of a remote device.
P
ARAMETERS The RTU’s ID, the byte code, and parameters (for some forms of
the command). All parameters are in decimal form (pay particular
attention to the byte code because it must be translated to
decimal).
R
ETURNS Status result, depends on command.
R
EMARKS This command is currently supported only by the A723 (series 3)
addITs and the A733 addWAVE RTUs.
E
XAMPLE analog 9473 0
Dev 9473: incoming RF 255, outgoing RF 255
Average method: 1 2 3 4 5 6 7 5 5 5 5 5 0 0 0 0
Error level: 0
OK