CHAPTER 3
Operations at the Application Level
95
The RF level is non-linear and results from a table (which you can
get from Adcon as an ASCII file). The value of the battery can be
computed as follows:
The digibyte is essentially the reflection of several inputs or
internal status bits on the A730MD; its structure is described
below:
For more details, refer to the user manual for the A730MD device
(addVANTAGE A730).
The A720 (addIT) Frames
The addIT uses a reduced frame type (38). No adapter use for
extending the inputs is possible.
Type 3 8
SIZE 14 (including the type byte).
F
ORMAT struct tlg_type38 {
BYTE RF_LevelIn;
BYTE RF_LevelOut;
BYTE DigiByte;
BYTE PulseCounter0;
BYTE PulseCounter1;
BYTE BatteryLevel;
BYTE Analog1;
BYTE Analog2;
BYTE Analog3;
BYTE Analog4;
BYTE Analog5;
BYTE Analog6;
BYTE Reserved;
Batt
V[]
BatteryLevel 20•
255
----------------------------------------------=
B7 B6
B5 B4
B3 B2
B1 B0
S.C.
AUX:4
N.U. RAI:3 RAI:4
AUX:2 AUX:3 AUX:5
S.C. = Solar Cell status N.U. = Not used RAI = Rain AUX = Aux